Jaehyek Choi Embedded/Firmware Engineer

eMMC UFS Issues 11

2016-12-26
Jaehyek

Component Feature

  • 16nm eMMC 4.5 4G
  • Controller :
  • Hy

Failure Symptom

  • Smart Phone hang-up, No Power-On
  • Read Reclaim Fail

Root Cause

  • Read Disturbance UECC error for file “Framework.odex” , size 10.1MB
  • Read count : 1.28M times
  • After E/W 0.1K, Under Read Stress Repeat Test , Read error over 100K times 001

Mechanism of Read Disturbance Failure

  • turn on the Pass Bais to neighbor cell within same block
  • turn off the Pass Bais to reading cell to read page data within same block
  • can read data for the cell
  • in case that the same cell is read repeatedly, it is possible to make a read disturbance sympton 002