Jaehyek Choi Embedded/Firmware Engineer

eMMC UFS Issues 06

2016-12-26
Jaehyek

Component Feature

  • eMCP eMMC
  • Controller :
  • Hy

Failure Symptom

  • no boot

Failure procedure

  • fail1 : Static Wear Leveling does not work in case that Sequential Writing continues to repeat on narrow area block
  • fail2 : Static Wear Leveling does not work in case that SPO continues to repeat after small Writing 001

Cause

  • fail1
    • on clean area, not on dirty area
    • 512KB Chunk Sequential Writing was done repeatedly on 1GB
    • Static Wear Leveling does not work properly 002
  • fail2
    • while valid data is full
    • small data was written repeatedly on 1GB
    • Erase counts on Over-provision area and 1GB range was increased rapidly
    • SPO during small data writing caused the Static Wear Leveling not work properly 003