eMMC UFS Issues 06
Component Feature
- eMCP eMMC
- Controller :
- Hy
Failure Symptom
Failure procedure
- fail1 : Static Wear Leveling does not work in case that Sequential Writing continues to repeat on narrow area block
- fail2 : Static Wear Leveling does not work in case that SPO continues to repeat after small Writing

Cause
- fail1
- on clean area, not on dirty area
- 512KB Chunk Sequential Writing was done repeatedly on 1GB
- Static Wear Leveling does not work properly

- fail2
- while valid data is full
- small data was written repeatedly on 1GB
- Erase counts on Over-provision area and 1GB range was increased rapidly
- SPO during small data writing caused the Static Wear Leveling not work properly