Jaehyek Choi Embedded/Firmware Engineer

eMMC & UFS FTL (3)

2016-12-07
Jaehyek
   

FTL Functions

Wear Leveling

  • Wear leveling software monitors Flash erase block cycling and guarantees that all erase block are cycled about the same number of times.
  • Some files are seldom changed, while others may be changed frequently. If all files were updated at the same frequency, wear leveling would not be necessary. 001

Handling Device Error

  • Handing Bad Block for NAND
  • NAND permits 1-2% factory or run time bad blocks
  • BD tract this information through marking to the head of block or separate table
  • BD have to have strategy to decide run-time bad block when read/write/erase error happens

  • Handling Bit error for NAND
  • One or a few bit error happens rarely in NAND.
  • Error collection code can allow the area to live instead of throw it away by marking Bad block

Power Loss Problem

  • Power loss break BD’s integrity in various way
  • Crash BD and make BD be disable to mount
  • Point wrong physical block for a virtual sector 002

  • Lost Data Case

003